Central City Scale · Central City, NE · Since 1974 800-582-3175 Service & Support Get a Quote
Central City Scale Get a quote

Libra Feed: Calibration

From the Agrimatics support center · Libra Feed · Getting Started · Original article

This should be done after your Rated Capacity and Sensitivity Numbers have been entered. Click here for an article on how to set your load cell ratings.

  1. Ensure load cell ratings (Rated Capacity and Sensitivity) have been found and entered in the Device tab.
  2. Ensure the Libra Feed device and app are paired and communicating.
  3. Ensure the mixer is empty and on level ground.
  4. Select the Device tab and tap Zero Scale .
  5. Select the Display tab and then tap Tare .
  6. Load the mixer with a known weight and note the reading from the large display on the app. Larger weights provide higher precision.
  7. Select the Device tab and enter the known weight as the Certified Reading .
  8. Enter the noted weight displayed by the as the Mixer Reading .
  9. Tap Calculate to compute a new Calibration Factor.
  10. Tap Save Settings .

For additional help the video tutorial below will show this process in-app:

Play video: Calibration


Need a hand? Central City Scale is an authorized Agrimatics distributor. Call 800-582-3175, Monday to Friday 8:00 to 5:00 Central, or go back to Libra Feed help.